Off Line Filters
The area of application comprises:
- secondary flow filtration in addition to the existing operating filter
- secondary flow filtration without the action of the operating filter
- filtration when filling the oil reservoir.
The filter unit must not be used to pump contaminated hydraulic fluids and is therefore designed without a switchover fitting to bypass the filter. The compact structural design on a base plate without pipe satisfies the prerequisites for small dimensions and high reliability.
The device is equipped with a gear pump driven by an E-motor. The flow conveyed by the geared pump is fed over a filter element to DIN 24550, T4, nominal size 1000.
Depending on the customer’s wishes, the filter fineness is either 4, 5, 7 or 10 μm(c). The contamination level of the filter element can be read off from a pressure display in the cover of the filter.
Key Features
- Both mobile and stationary
- Mineral oils, emulsions and most synthetic hydraulic fluids
- Hydraulic pressures up to 10 bar
- Flows up to 320 l/min
- Filter fineness 5-12 microns absolute
- Interpore fleece media
- Hose-lance protective filter option on mobile units
- Plate and tubular heat exchangers available